Brocade Silkworm 12000 fabric switch |
The new
Brocade® SilkWorm® 12000 director is a high port
density, multi-protocol core fabric switch offering
64-port and dual 64-port configurations in a single
enclosure. It is designed for deploying enterprise-class
Storage Area Networks (SANs) in mission-critical
environments. |
|
|
Spec Summary |
 |
|
|
 |
 |
Fibre Channel
ports: |
128
universal ports (E,F and FL)
Up to eight 16-port Fibre Channel modules
|
 |
Fabric
latency: |
<2.1 msec
any port to any port at 2 Gb/sec, cut
through routing
|
 |
Maximum frame
size: |
2112-byte
payload
|
|
|
|
|
Applications |
Disk mirroring
Disk SANs employing the Brocade SilkWorm 12000
director can be implemented to improve the
manageability of local and remote mirroring systems,
keeping online data better protected and more
available. |
Storage consolidation
By consolidating storage with a SAN using the
Brocade SilkWorm 12000 director, you can better
manage and protect all of your business critical
information. |
Disaster recovery
Brocade SilkWorm directors play a critical role in
complete disaster recovery systems, including SANs
for clustering/fail-over, remote data vaulting and
backup and restore functions. |
Backup and restore
Brocade SilkWorm directors are at the center of
storage area networks (SANs) used to enable backup
and restore to be shared across departments and data
centers, reducing costs and simplifying management. |
|
|
Benefits |
Simplified SAN deployment
The SilkWorm 12000 director simplifies enterprise
SAN deployment by combining high port density with
exceptional scalability, performance, reliability
and availability. |
Scalability
The SilkWorm 12000 director can connect from
hundreds to thousands of devices within the SAN. |
Simplified management
The SilkWorm 12000 director simplifies management by
networking core and edge switches under Brocade
Fabric OS™, an embedded real-time operating system.
This enables heterogeneous device connectivity,
automatic data routing and rerouting, self-healing
capabilities and scalable connectivity. |
Investment protection
The SilkWorm 12000 director provides a seamless
upgrade path and backward and forward compatibility
with SilkWorm® entry, midrange and port aggregation
offerings. |
High availability
The SilkWorm 12000 director meets enterprise-class
99.999 percent availability requirements with
redundant, hot-pluggable components, no single
points of failure within the switch and
non-disruptive software upgrades. |
|
|
Features |
Brocade Fabric Access™ Application
Programming Interface (API)
The API provides application developers with
programmatic control of the fabric for discovery,
zone, performance, and switch control functions. |
Brocade® Inter-Switch Link (ISL) Trunking
Provides a high-speed data path between switches. |
Brocade Secure Fabric OS
The SilkWorm 12000 director supports Brocade Secure
Fabric OS, a comprehensive SAN security architecture
based on state-of-the-art networking security
technology that addresses a wide variety of
vulnerabilities within the SAN fabric. |
Brocade Frame Filtering™
To improve security and manageability, advanced
Brocade Frame Filtering™ intelligence is built
directly into the SilkWorm® 12000 ASIC technology.
This design enables new capabilities such as fabric
zoning based on Logical Unit Number (LUN), World
Wide Name (WWN) or protocol. |
Brocade Fabric Shortest Path First (FSPF)
FSPF enables the fabric to automatically isolate
problems and reroute traffic around failed links
onto alternate paths—supporting availability for
mission-critical enterprise applications. |
|
|
Specifications |
Performance |
 |
 |
|
|
|
 |
 |
|
Fabric
latency: |
<2.1 msec any port
to any port at 2 Gb/sec, cut through routing
|
|
Maximum frame size: |
2112-byte payload
|
|
Performance: |
1.063 Gb/sec line
speed, full duplex
2.125 Gb/sec line speed, full duplex
Auto-sensing of 1 Gb/sec and 2 Gb/sec port speeds
Optionally programmable to fixed port speed
Speed matching between 1 Gb/sec and 2 Gb/sec ports
|
|
ISL
Trunking: |
Up to four 2.125
Gb/sec ports per trunk
Up to 8.5 Gb/sec per ISL trunk
|
|
Aggregate bandwidth: |
512 Gb/sec
end-to-end
|
 |
 |
|
Capacity |
 |
 |
|
|
|
 |
 |
|
Fibre
Channel ports: |
128 universal
ports (E,F and FL)
Up to eight 16-port Fibre Channel modules
|
|
Scalability: |
Full-fabric
architecture with 239 switches maximum
|
 |
 |
|
Availability |
 |
 |
|
|
|
 |
 |
|
Control Processor: |
Redundant
(active/standby) Control Processor modules;
Automatic failover; Non-disruptive software
upgrades; Dual-flash memory on each Control
Processor to store two software images
|
|
Modules: |
Hot-swappable
|
|
Backplane: |
Fully passive
|
|
Input
power: |
Dual AC inputs
|
|
Chassis power: |
Four AC-DC power
supply modules, 2N redundant
|
|
Cooling: |
Three blower
assembly modules (two operatonal required)
|
 |
 |
|
Compatibility |
 |
 |
|
|
|
 |
 |
|
Classes of service: |
Class 2, Class 3,
Class F (inter-switch frames)
|
|
Port
types: |
FL-Port, F_Port,
and E_Port; self-discovery based on switch type (U_Port);
optional port type control
|
|
Data
traffic types: |
Fabric switches
support unicast, multicast (256 groups), and
broadcast
|
|
Media
types: |
Small Form-factor
Pluggable (SFP), LC connector;
|
|
Laser:
|
Short-Wave Laser (SWL)
up to 1,640 ft (500 m); Long-Wave Laser (LWL) up to
6.2 mi (10 km); distance depends on fiber optic
cable and port speed
|
 |
 |
|
Management |
 |
 |
|
|
|
 |
 |
|
Fabric
services: |
Simple Name
Server, Registered State Change Notification (RSCN),
Alias Server (multicast), Brocade Advanced Zoning,
WEB TOOLS, Fabric Watch, Extended Fabrics, Remote
Switch, ISL Trunking, End-to-End Performance
Monitoring (some services are optional)
|
|
Supported software: |
Telnet; SNMP (FE
MIB, FC Management MIB); WEBTOOLs, Fabric Watch,
Fabric Manager
|
|
Management: |
Telnet, SNMP (FE
MIB, FC Management MIB); WEB TOOLS; Fabric Wathc;
Fabric Access layer
|
|
Management access: |
10/100 Ethernet
(RJ-45), i-band over Fibre Channel (requires
fabric); two serial ports (DB-9) per Control
Processor module
|
|
Diagnostics: |
POST and embedded
online/offline diagnostics
|
 |
 |
|
Mechanical |
 |
 |
|
|
|
 |
 |
|
Enclosure: |
Rear panel-to-door
airflow
|
|
Ports
per rack: |
Up to 384 ports
per 42 u rack
|
|
Width
: |
17.22 in (43.74
cm)
|
|
Weight: |
215-250 lb (98-113
kg)
|
|
Mounting options: |
Rack-mountable in
standard 19 inch EIA rack
Telco-style mid-mounting available
|
|
Depth:
|
Without door:
27.90 in (70.90 cm)
With door: 29.20 in (74.20 cm)
|
|
Height: |
24.11 in (61.24
cm) 14 u
|
 |
 |
|
Environmental |
 |
 |
|
|
|
 |
 |
|
Temperature: |
Operating: 0° to
+104° F (0° to +40° C)
|
|
Humidity: |
Operating: 20%–85%
noncondensing at +104° F (+40° C)
|
|
Altitude: |
0 - 15,840 ft (0 -
3 km)
|
|
Vibration: |
Operating: 0.5 G
p-p, 5-500-5 Hz
Nonoperating: 2 G , 0-500 Hz
|
|
Shock:
|
20 G, 2 ms, half
sine
|
 |
 |
|
Power |
 |
 |
|
|
|
 |
 |
|
Supported power range: |
Nominal: 200 to
240 VAC, single phase
Operational: 180 to 264 VAC auto-sensing
Maximum 12 Amps at 180 VAC
Maximum 2300 Volt-Amps
|
|
Frequency: |
47-63 Hz
|
|
In-rush current: |
40 A maximum, <
1/4 AC cycle, per AC input
|
 |
 |
|
Regulatory Compliance |
 |
 |
|
|
|
 |
 |
|
Canada: |
Safety: CSA 60950
EMC: ICES-003 Class A
|
|
United
States: |
Safety: UL 60950
EMC: FCC Part 15 Class A
|
|
Japan:
|
Safety: IEC 60950
A4 EMC: VCCI Class A
|
|
European Community: |
Safety: EN60950
TUV, NEMKO EMC: EN55022 Level A EN55024
|
|
Australia/New Zealand: |
EMC: AS/NZ 3548
|
|
International: |
Safety: IEC 60950
EMC: CISPR 22
|
|
Fibre
Channel standards and revisions: |
FC-AL, ANSI
X3.272: 1996 FC-AL-2, NCITS 332: 1999 FC-FLA, NCITS
TR-20: 1998 FC-GS-2, NCITS 288: 1999 FC-GS-3, Rev
7.01 FC-FG, ANSI X3.289: 1996 FC-MI, Rev 1.5 FC-PH,
ANSI X3.230: 1994 FC-PH-2, ANSI X3.297: 1997
FC-PH-3, ANSI X33.303: 1998 FC-PLDA, NCITS TR-19:
1998 FC-SW, NCITS 321: 1998 FC-SW-2, Rev. 4.9 FC-VI,
Rev 1.61 IPFC, RFC 2625 FCP, ANSI X3.269:1996 FCP-2,
Rev 7 SCSI Enclosure Services, Rev 8b
|
|
|
|